    Flow Rate Calibration Ultrasonic Flow Measurement TF1100-CH


    Transition time ultrasonic flowmeter working method. The battery is rechargeable for 14 hours, and the 4-line backlight display makes the reading more intuitive. The clamp-on ultrasonic sensor (sensor) is installed on the outer surface of the pipeline and is used for non-invasive and non-invasive flow measurement of the liquid and liquefied gas filled in the pipeline. Three pairs of sensors are sufficient to cover the most common pipe diameter ranges. The user can hold and operate the flow meter host by hand. This flexible and easy-to-use flow meter is an ideal tool to support service and maintenance activities. It can also be used to control or even temporarily replace permanently installed instruments.


    Flow Rate Calibration Ultrasonic Flow Measurement TF1100-CH​ Features:

    1.14 hours battery (rechargeable), back-lit 4 lines display.
    2.Can be used for mobile measurement, flow rate calibration, data comparing, meters running status checking.
    3.Non-invasive transducers.
    4.Data logger function.
    5.Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range: -35℃~200℃.

    Flow Rate Calibration Ultrasonic Flow Measurement Applications:

    Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
    Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
    Petrochemical industry
    Refrigeration and air conditioning systems

    Metallurgy and mining applications
    Food , beverage and pharmaceutical industry
    Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
    Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.

    General


    ● Service and maintenance
    ● Support of commissioning process and installation
    ● Replacement of defective devices
    ● Performance and efficiency measurement
    - Evaluation and assessments
    - Capacity measurement of pumps
    - Monitoring of regulating valves

    Non invasive 12m/s IP68 Transit Time Ultrasonic Flow Meter

    Specifications: Transmitter

    Measurement principleUltrasonic transit-time difference correlation principle
    Resolution0.25mm/s
    Repeatability0.2% of reading
    Accuracy±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
    Response time0.5s
    Flow velocity range0.01 to 12 m/s, bi-directional
    Sensitivity0.003m/s
    Damping of displayed value0-99s(selectable by user)
    Liquid Types Supportedboth clean and somewhat dirty liquids with turbidity <10000 ppm
    Power SupplyAC: 85-265V Up to 14 h with fully charged internal batteries
    Enclosure typeHandheld, Portable
    Degree of protectionIP65 according to EN60529
    Housing materialABS( UL 94HB)
    Operating temperature-20℃ to +60℃
    Display4 line×16 English letters LCD graphic display, backlit
    UnitsUser Configured (English and Metric)
    RateRate and Velocity Display


    Specifications: Transducer

    Degree of protectionIP65 according to EN60529.(IP67 or IP68 Upon request)
    Pipe diameter range20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L
    Material of transducerAluminum for standard temp. sensor, and peek for high temp. sensor
    Suited Liquid TemperatureStd. Temp.: -35℃~85℃ for short periods up to 120℃
    High Temp.: -35℃~200℃ for short periods up to 250℃
    Transducer SizeType S 48(h)*28(w)*28(d)mm
    Type M 60(h)*34(w)*33(d)mm
    Type L 80(h)*40(w)*42(d)mm
    Cable LengthStd: 5m


    Data sheet download TF1100-CH transit-time handheld ultrasonic flowmet...
    Manual Download TF1100-CH transit-time handheld flowmeter Manual.p...

    Dimensional Sketches

    Transmitter:
    Non invasive 12m/s IP68 Transit Time Ultrasonic Flow Meter
    Transducer:

    Non invasive 12m/s IP68 Transit Time Ultrasonic Flow Meter

    Packing & Delivery


    With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.
    Non invasive 12m/s IP68 Transit Time Ultrasonic Flow MeterNon invasive 12m/s IP68 Transit Time Ultrasonic Flow MeterNon invasive 12m/s IP68 Transit Time Ultrasonic Flow Meter

    Delivery

    Clamp On Handheld Ultrasonic Flow Meter TF1100-CH for water and chilled water application
    Standard meter: 3-7 days
    Special meter: pls contact us
    Express, by air, by sea can be optional.

    Quality Non invasive 12m/s IP68 Transit Time Ultrasonic Flow Meter for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Lanry Instruments (Shanghai) Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)