Sign In | Join Free | My himfr.com
Home > Portable Ultrasonic Flow Meter >

Ultrasonic Flow Meter For Clean And Dirty Liquid

    Buy cheap Ultrasonic Flow Meter For Clean And Dirty Liquid from wholesalers
     
    Buy cheap Ultrasonic Flow Meter For Clean And Dirty Liquid from wholesalers
    • Buy cheap Ultrasonic Flow Meter For Clean And Dirty Liquid from wholesalers

    Ultrasonic Flow Meter For Clean And Dirty Liquid

    Ask Lasest Price
    Brand Name : Lanry
    Model Number : TF1100-EP
    Certification : CE ISO9000
    Price : Negotiable
    Supply Ability : 100Unit/Units per Week
    • Product Details
    • Company Profile

    Ultrasonic Flow Meter For Clean And Dirty Liquid

    Digital Tranist-Time Ultrasonic Flow Meter for both clean and dirty liquids​


    Digital Portable Tranist-Time Ultrasonic Flowmeter works on the transit-time method.

    The clamp-on ultrasonic sensor is installed on the outer surface of the pipeline and is used for non-invasive and non-invasive flow measurement of the liquid and liquefied gas filled in the pipeline. Three pairs of sensors are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability enables it to perform a complete analysis of the thermal energy usage of any facility. This flexible and easy-to-use flow meter is an ideal tool to support service and maintenance activities. It can also be used for control or even temporary replacement of permanently installed instruments.


    Digital Tranist-Time Ultrasonic Flow Meter for both clean and dirty liquids​ Features:


    1.50-hour battery (rechargeable), back-lit 4 lines display all integrated into a rugged, watertight enclosure.
    2.The heat measurement function by configuring with paired temperature sensors.
    3.Non-invasive transducers.
    4.Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range: -35℃~200℃.
    5.Data logger function.


    Digital Tranist-Time Ultrasonic Flow Meter for both clean and dirty liquids​ Application:


    Metallurgy and mining applications
    Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.
    Food , beverage and pharmaceutical industry
    Refrigeration and air conditioning systems

    Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
    Petrochemical industry

    Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc


    Standard Digital Tranist-Time Ultrasonic Flow Meter for both clean and dirty liquids Specifications:

    Transmitter :

    Measurement principle

    Ultrasonic transit-time difference correlation principle

    Flow velocity range

    0.01 to 12 m/s, bi-directional

    Resolution

    0.25mm/s

    Repeatability

    0.2% of reading

    Accuracy

    ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s

    Sensitivity

    0.003m/s

    Damping of displayed value

    0-99s(selectable by user)

    Liquid Types Supported

    both clean and somewhat dirty liquids with turbidity <10000 ppm

    Response time0.5s

    Power Supply

    AC: 85-265V Up to 50 h with fully charged internal batteries

    Enclosure type

    Portable

    Units

    User Configured (English and Metric)

    Rate

    Rate and Velocity Display

    Totalized

    gallons, ft³, barrels, lbs, liters, m³,kg

    Thermal energy

    unit GJ,KWh can be optional

    Communication

    4~20mA,OCT, Relay, RS232, RS485 (Modbus),Logged data

    Security

    Keypad lockout, system lockout


    Specifications:

    Transducer:


    Degree of protection

    IP65 according to EN60529.(IP67 or IP68 Upon request)

    Suited Liquid Temperature

    Std. Temp.: -35℃~85℃ for short periods up to 120℃

    High Temp.: -35℃~200℃ for short periods up to 250℃

    Pipe diameter range

    20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L

    Transducer Size

    Type S 48(h)*28(w)*28(d)mm

    Type M 60(h)*34(w)*32(d)mm

    Type L 80(h)*40(w)*42(d)mm

    Material of transducer

    Aluminum for standard temp. sensor,and peek for high temp. sensor

    Temperature Sensor

    Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%

    Cable LengthStd:5m

    Application pictures:


    Ultrasonic Flow Meter For Clean And Dirty Liquid

    Datasheet Download TF1100-EP transit-time portable ultrasonic flowmet...

    Manual Download TF1100-EP portable flowmeter manual.pdf


    Packing & Delivery


    TF1100-EP Transit-Time Portable Ultrasonic Flowmeter with data logger function


    With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.


    Ultrasonic Flow Meter For Clean And Dirty Liquid

    Delivery

    TF1100-EP Transit-Time Portable Ultrasonic Flowmeter with data logger function

    Standard meter: 3-7 days

    Special meter: pls contact us

    Express, by air, by sea can be optional.

    Quality Ultrasonic Flow Meter For Clean And Dirty Liquid for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Lanry Instruments (Shanghai) Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)