Sign In | Join Free | My himfr.com
Home > Handheld Ultrasonic Flow Meter >

Flow Rate Calibration Ultrasonic Flow Measurement

    Buy cheap Flow Rate Calibration Ultrasonic Flow Measurement from wholesalers
     
    Buy cheap Flow Rate Calibration Ultrasonic Flow Measurement from wholesalers
    • Buy cheap Flow Rate Calibration Ultrasonic Flow Measurement from wholesalers

    Flow Rate Calibration Ultrasonic Flow Measurement

    Ask Lasest Price
    Brand Name : Lanry
    Model Number : TF1100-CH
    Certification : ISO9000, CE, CPA,CMC
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 1000pcs/month
    Delivery Time : 7-10 working days
    • Product Details
    • Company Profile

    Flow Rate Calibration Ultrasonic Flow Measurement

    Flow Rate Calibration Ultrasonic Flow Measurement TF1100-CH

    Transit-time Ultrasonic Flow Meter work with method. The 14 hours battery can be recharged, The back-lit 4 lines display makes the readings more intuitive. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges.
    User can use hand to hold as well as to operate the flow meter main unit. This flexible and easy-to-use flow meter is an ideal tool to support service and maintenance activities.It can also be used for the control or even for the temporary replacement of permanently installed meters.

    Flow Rate Calibration Ultrasonic Flow Measurement TF1100-CH​ Features:

    1)Can be used for mobile measurement, flow rate calibration, data comparing, meters running status checking.
    2)Non-invasive transducers.
    3)Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range: -35℃~200℃.
    4)Works reliably in both clean and somewhat dirty liquids with turbidity<10000ppm.


    Flow Rate Calibration Ultrasonic Flow Measurement Applications:

    Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
    Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
    Petrochemical industry
    Refrigeration and air conditioning systems
    Food , beverage and pharmaceutical industry
    Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
    Metallurgy and mining applications
    Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.

    General

    ● Support of commissioning process and installation
    ● Service and maintenance
    ● Replacement of defective devices
    ● Performance and efficiency measurement
    - Evaluation and assessments
    - Capacity measurement of pumps
    - Monitoring of regulating valves

    Flow Rate Calibration Ultrasonic Flow Measurement

    Specifications: Transmitter

    Measurement principleUltrasonic transit-time difference correlation principle
    Flow velocity range0.01 to 12 m/s, bi-directional
    Resolution0.25mm/s
    Repeatability0.2% of reading
    Accuracy±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
    Response time0.5s
    Sensitivity0.003m/s
    Damping of displayed value0-99s(selectable by user)
    Liquid Types Supportedboth clean and somewhat dirty liquids with turbidity <10000 ppm
    Power SupplyAC: 85-265V Up to 14 h with fully charged internal batteries
    Enclosure typeHandheld, Portable
    Degree of protectionIP65 according to EN60529
    Housing materialABS( UL 94HB)
    Operating temperature-20℃ to +60℃
    Display4 line×16 English letters LCD graphic display, backlit
    UnitsUser Configured (English and Metric)
    RateRate and Velocity Display


    Specifications: Transducer

    Degree of protectionIP65 according to EN60529.(IP67 or IP68 Upon request)
    Pipe diameter range20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L
    Suited Liquid TemperatureStd. Temp.: -35℃~85℃ for short periods up to 120℃
    High Temp.: -35℃~200℃ for short periods up to 250℃
    Transducer SizeType S 48(h)*28(w)*28(d)mm
    Type M 60(h)*34(w)*33(d)mm
    Type L 80(h)*40(w)*42(d)mm
    Material of transducerAluminum for standard temp. sensor, and peek for high temp. sensor
    Cable LengthStd: 5m


    Data sheet download TF1100-CH transit-time handheld ultrasonic flowmet...
    Manual Download TF1100-CH transit-time handheld flowmeter Manual.p...

    Dimensional Sketches

    Transmitter:
    Flow Rate Calibration Ultrasonic Flow Measurement
    Transducer:

    Flow Rate Calibration Ultrasonic Flow Measurement

    Packing & Delivery


    With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.
    Flow Rate Calibration Ultrasonic Flow MeasurementFlow Rate Calibration Ultrasonic Flow MeasurementFlow Rate Calibration Ultrasonic Flow Measurement

    Delivery

    Clamp On Handheld Ultrasonic Flow Meter TF1100-CH for water and chilled water application
    Standard meter: 3-7 days
    Special meter: pls contact us
    Express, by air, by sea can be optional.





















































    Quality Flow Rate Calibration Ultrasonic Flow Measurement for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Lanry Instruments (Shanghai) Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)