    Brand Name : Lanry
    Model Number : TF1100-EI
    Certification : CE
    Price : Negotiable
    Supply Ability : 1000 Unit/Week
    • Product Details
    • Company Profile

    Fiberglass Pipe Ultrasonic Liquid Flow Meter Insertion Installation 4-20mA Pulse Output

    Fiberglass Pipe Ultrasonic Flowmeter Insertion installation with 4-20mA pulse output

    TF1100-EI transit-time Insertion ultrasonic flowmeter provides abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The proprietary signal quality tracking and self-adapting technologies allow system to optimally adapt to different pipe materials automatically. Due to hot-tapped mounting of insertion transducers, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy.

    It is ok for Fiberglass pipe application and install the sensor with Hoop, if you need more information and application picture, pls contact us.


    Data sheet Download TF1100-EI transit-time insertion ultrasonic flowm...

    Manual Download TF-1100-EC&EI heat meter Manual.pdf


    Features:

    1. Hot-tapped installation, no pipe line flow interrupted.
    2. No moving parts, no pressure drop, no maintenance.
    3. Spool-piece transducer for best accuracy and better long-term stability.
    4. High temp. Insertion transducers are suitable for high temperature of -35℃~150℃.
    5. Wide bi-directional Flow range of 0.03 to 36 m/s, and wide range of pipe sizes from DN65 to DN6000.
    6. Data logger function.
    7. The heat measurement function by configuring with paired temperature sensors

    Application:

    Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
    Petrochemical industry
    Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
    Refrigeration and air conditioning systems
    Food , beverage and pharmaceutical industry
    Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
    Metallurgy and mining applications
    Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.


    Fiberglass Pipe Ultrasonic Liquid Flow Meter Insertion Installation 4-20mA Pulse Output Fiberglass Pipe Ultrasonic Liquid Flow Meter Insertion Installation 4-20mA Pulse Output


    Specifications: Transmitter


    Measurement principleUltrasonic transit-time dfference correlation principle
    Flow velocity range0.01 to 12 m/s, bi-directional
    Reaolution0.25mm/s
    Repeatability0.2% of reading
    Accuracy±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
    Resonse time0.5s
    Sensitivity0.003m/s
    Damping of displayed value0-99s(selectable by user)
    Liquid Types Supportedboth clean and somewhat dirty liquids with turbidity <10000 ppm
    Power SupplyAC: 85-265V DC: 24V/500mA
    Enclosure typeWall-mounted
    Degree of protectionIP66 according to EN60529
    Operating temperature-10℃ to +60℃
    Housing materialFiberglass
    Display4 line×16 English letters LCD graphic display, backlit
    UnitsUser Configured (English and Metric)
    RateRate and Velocity Display
    Totalizedgallons, ft³, barrels, lbs, liters, m³,kg
    Thermal energyunit GJ,KWh can be optional
    Communication4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),datalogger
    SecurityKeypad lockout, system lockout
    Size244*196*144mm
    Weight2.4kg

    Specifications: Transducer

    Degree of protectionIP67 or IP68 according to EN60529
    Suited Liquid TemperatureStd. Temp.: -35℃~85℃
    High Temp.: -35℃~150℃
    Pipe diameter rangeDN65-6000
    Transducer SizeType S Φ58*199mm
    Material of transducerStainless Steel
    Cable LengthStd: 10m
    Temperature SensorPt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%