    Ask Lasest Price
    Brand Name : Lanry
    Model Number : TF1100-EI
    Certification : CE
    Price : Negotiable
    Supply Ability : 100unit/week
    • Product Details
    • Company Profile

    Insertion Type Transit Time Ultrasonic Flow Meter For Waste Water Industry

    Insertion type ultrasonic flow meter TF1100-EI for waste water industry
    Insertion type ultrasonic flow meter TF1100-EI is widly used in many fileds, such as water and waste water industry - hot water, cooling water, potable water, sea water etc., chemical industry, petrochemical industry and so on.
    Insertion type ultrasonic flow meter TF1100-EI provides abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The proprietary signal quality tracking and self-adapting technologies allow system to optimally adapt to different pipe materials automatically. Due to hot-tapped mounting of insertion transducers, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy.
    Insertion type ultrasonic flow meter TF1100-EI for waste water industry Features:
    1. Hot-tapped installation, no pipe line flow interrupted
    2. Thermal energy measurement capability can be optional.
    3. Wide bi-directional flow range of 0.01 m/s to 12 m/s..
    4. Wide liquid temperature range: -35℃~200℃.
    5. For commonly used pipe materials and diameters from 20mm to over 6.0m.

    6. Data logger function for insertion ultrasonic flow meter


    Application

    General
    ● Service and maintenance

    ● Energy efficiency audits

    ● Replacement of defective devices

    ● Support of commissioning process and installation

    ● Performance and efficiency measurement
    - Evaluation and assessments
    - Capacity measurement of pumps
    - Monitoring of regulating valves

    Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
    Petrochemical industry

    Refrigeration and air conditioning systems
    Food , beverage and pharmaceutical industry

    Metallurgy and mining applications

    Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
    Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
    Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.

    Insertion Type Transit Time Ultrasonic Flow Meter For Waste Water Industry

    Specifications:Transmitter


    Measurement principleUltrasonic transit-time difference correlation principle
    Flow velocity range0.01 to 12 m/s, bi-directional
    Resolution0.25mm/s
    Repeatability0.2% of reading
    Accuracy±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
    Response time0.5s
    Sensitivity0.003m/s
    Damping of displayed value0-99s(selectable by user)
    Liquid Types Supportedboth clean and somewhat dirty liquids with turbidity <10000 ppm
    Power SupplyAC: 85-265V DC: 24V/500mA
    Enclosure typeWall-mounted
    Degree of protectionIP66 according to EN60529
    Operating temperature-20℃ to +60℃
    Housing materialFiberglass
    Display4 line×16 English letters LCD graphic display, backlit
    UnitsUser Configured (English and Metric)
    RateRate and Velocity Display
    Totalizedgallons, ft³, barrels, lbs, liters, m³,kg
    Thermal energyunit GJ,KWh can be optional
    Communication4~20mA(accuracy 0.1%),Frequency(1-9999Hz), Relay, RS232, RS485 (Modbus),Logged data

    Specifications:Transducer


    Degree of protectionIP67 or IP68 according to EN60529
    Suited Liquid TemperatureStd. Temp.: -35℃~85℃
    High Temp.: -35℃~150℃
    Pipe diameter rangeDN65-6000
    Transducer SizeType S Φ58*199mm
    Material of transducerStainless Steel
    Cable LengthStd: 10m
    Temperature Sensor

    Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%



    Packing & Delivery


    Inserted Type Ultrasonic Flow Meter With 4-20mA Output for clean liquid application


    With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.
    Insertion Type Transit Time Ultrasonic Flow Meter For Waste Water IndustryInsertion Type Transit Time Ultrasonic Flow Meter For Waste Water Industry
    Insertion Type Transit Time Ultrasonic Flow Meter For Waste Water IndustryInsertion Type Transit Time Ultrasonic Flow Meter For Waste Water Industry

    Delivery

    Inserted Type Ultrasonic Flow Meter With 4-20mA Output

    Standard meter: 3-7 days

    Special meter: pls contact us

    Express, by air, by sea can be optional.

    Quality Insertion Type Transit Time Ultrasonic Flow Meter For Waste Water Industry for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Lanry Instruments (Shanghai) Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)